Consulting Engineers

 

UPS & Battery Backup Systems

InRow RC, 600mm, Chilled Water, 380-415V, 50/60Hz

InRow RC, 600mm, Chilled Water, 380-415V, 50/60Hz

Close-coupled, chilled water cooling for medium to large data centers

Total cost of Ownership

Row-based architecture - Captures hot exhaust air directly from the IT equipment, thereby increasing the unit's sensible cooling capacity over traditional cooling architectures.

Variable speed fans - Variable speed fans reduce energy consumption during off-peak cooling periods.

Manageability

Building management system integration - Send alarms and data points allowing you to manage critical building infrastructure from a single system.

Microprocessor controller - Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.

Real-Time capacity monitoring - Real-time display of current and available cooling.

Availability

Active response controls - Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Dual A-B power inputs - Draws power from the UPS for power protection with dual feeds for redundancy.

Top and bottom chilled water connections - Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.

Predictable cooling - Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.

Rack inlet control - Rack inlet control guarantees inlet temperature to IT equipment.

Galaxy VX

Highly efficient 3-phase power protection with flexible operating modes
500 to 1500kVA

Part of Galaxy

Featuring ultra-efficient ECOnversion mode

Features

500 to 1500kW N+1
The Schneider Electric Galaxy VX UPS is a scalable, high-performance extension of the Galaxy V-Series solutions, designed for large data center and industrial applications:

  • Lower your energy costs and meet changing business requirements, with 99% efficiency in ECOnversion mode.
  • Provide excellent power quality in demanding electrical environments.
  • Install and deploy your UPS quickly.
  • Manage your power anywhere. Galaxy VX supports local and remote communication via touchscreen, Web interface, Modbus, and the Schneider Electric StruxureWare for Data Center Expert solution.

Benefits

Availability

  • Parallel-capacity capable - Increases total power capacity by using multiple uninterruptible power supplies simultaneously.
  • Compatible with Schneider Electric's lithium ion battery solution - Reduces system footprint and weight, cooling and maintenance requirements, and total cost of ownership; offers double the life of VRLA batteries; and improves backup storage predictability and manageability.
    Click here for more details.
  • Internal backfeed protection - Increases system defense from power anomalies.
  • Energy storage flexibility - Conventional flooded and modular battery offer along with different charging modes allows tailoring to specific back-up requirements.
  • Parallel-redundant capable - Power the connected equipment with multiple uninterruptible power supplies to increase system redundancy

Serviceability

  • StruxureOn enabled - Simplify maintenance and operation of your equipment through the use of vendor-neutral, cloud-based software and services.
  • Multiple levels of service - With the option of packages or individual service components, our services are structured to allow you to pick and choose what you would like APC to do for you.
  • StruxureWare Data Center Expert compatible - Enables centralized management via StruxureWare Data Center Expert.
  • Front-access servicing - Simplifies installation and UPS maintenance while minimizing space requirements.
  • 5x8 Start-up service included - Required for full coverage of factory warranty

Total cost of Ownership

  • Wide input voltage range - Designed for harsh electrical environments to save battery life.
  • ECOnversion mode - Operating mode that ensures ultra high efficiency while charging the batteries, conditioning the load power factor and ensuring a Class 1 output voltage regulation.
  • Input Power Factor Correction - Minimizes installation costs by enabling the use of smaller generators and cabling.
  • ECO Mode - Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
  • Robust operation - No power derating in kW up to 40 degrees C or 104 degrees F.

Galaxy VS                                                                         

  

Highly efficient 20 to 100 kW (480 V), 10 to 150 kW (400 V), and 10 to 50 kW (208 V) 3-phase UPS for edge, small, and medium data centers and other business-critical applications.

Part of Galaxy

Increased availability. Reduced operating costs. First class power protection for critical infrastructure.

 

Eaton 9PX UPS 

The Eaton 9PX UPS 5-22kVA provides energy-efficient power protection for small & medium Datacentres, IT rooms and Infrastructure. Delivering double conversion protection with 40% less energy usage and 28% more power 9PX is the perfect UPS for IT and Facility managers that are concerned by energy cost and are looking for next generation power protection solutions.

Eaton 9PX - Features

  • Online double conversion topology
  • Energy efficient (up to 95% in Online mode, 98% in high-efficiency mode, ENERGY STAR® qualified UPS)
  • Next-generation graphical LCD display (7 languages)
  • Provides more real power (watts) to protect more equipment with a 0.9 power factor
  • Parallel operation using HotSync technology
  • Maintenance ByPass available as standard (on HotSwap/BP version)
  • Energy metering - kWh values can be monitored using the LCD or Eaton’s Intelligent Power Software Suite
  • Compatible with Virtual environments (VMware, Hyper-V, Citrix Xen, Redhat)